The temperature read directly on an ordinary thermometer.
Wet bulb dry bulb psychrometric chart.
The relative humidity is approximately 50 the humidity ratio is approximately 65 grains h2o lb dry air.
Dry wet bulb temperature axis on psychrometric chart.
The state of air with dry bulb temperature 75 o f and wet bulb temperature 62 5 o f can be visualized in the psychrometric chart as indicated below.
It includes a dry bulb thermometer a wet bulb thermometer and a psychrometric chart a graph that plots the relationships between the dry and wet bulb temperature relative humidity and dew point at constant pressure.
Psychrometric chart includes so many axis which represent different parameters of air.
Two independent intensive properties are required to completely specify the state of air in the psychrometric chart.
The higher its dew point temperature.
Example the state of air in the psychrometric chart.
Properties of atmospheric air such as the dry bulb temperature the wet bulb temperature the dew point temperature the specific humidity the relative humidity specific enthalpy and specific volume are discussed in relation to the psychrometric chart below.
Now we are going to learn two of those axis dry bulb temperature and wet bulb temperature.
Wet bulb temp c.
Dry bulb temp c.
To use find the vertical line for the dry bulb temperature at the bottom of the chart and the slanted line for the wet bulb temperature at the curved top left edge.
Dry bulb temperature is located on the horizontal or x axis of the psychrometric chart and lines of constant temperature are represented by vertical chart lines.
If the air is flowing.
Relative humidity temperature in.
Since this temperature is so commonly used assume that temperatures are dry bulb temperatures unless otherwise designated.
The psychrometric chart gives the relative humidity for a given wet bulb and dry bulb temperature.
Altitude above sea level m.
The wet bulb temperature is the temperature of an object that can be achieved through evaporative cooling assuming good air flow and that the ambient air temperature remains the same.
When dry bulb and wet bulb temperatures of the air are known the dew point temperature can be plotted on the psychrometric chart fig.
Determine the properties of the air at state point 2 and compare them with those at state point 1.
Dry bulb temperature and 57 c wet bulb temperature experiences a temperature drop of 3 c as it passes through the 1 2 m wide stack of lumber.
By combining the dry bulb and wet bulb temperature in a psychrometric chart or mollier diagram the state of the humid air.
When we know dry bulb temperature and wet bulb temperature.
A process in which there is no change of dry bulb temperature.